Transmiter & Gauge | |||
20 | VOLUME BOTTLE, SS316, 1/4 in. FNPT, 150 cm3, 1800 psig (124 bar) |
Swagelok, MACIS, Amot, Olaer, SPIRAX-SARCO or Equal /EU/G7/Singapore | 316L-HDF4-150 or Equal |
CABINET & ACCESSORIES | |||
2 | FLAME ARRESTOR, 1" NPTF, SS316 | PROTECTOSEAL or Equal /EU/G7/Singapore |
F671 or Equal |
1 | FILLER CAP, 2" SS316 | CAPL, Parker, Lenz or Equal /EU/G7/Singapore |
CAPL-01 or Equal |
13 | START PUSHBUTTON FOR HP/MP/FILTRATION PUMPS (NC/NO-MOMENTARY) C/W IL & EOL RESISTOR OPEN/CLOSE PUSHBUTTON FOR VALVE (NC/NO- MOMENTARY) | RSTAHL, BARTEC, IDEC, ALLEN BRADLEY or Equal/ /EU/G7/Singapore, Mexico, Australia |
8003/111-001 or Equal |
5 | STOP PUSHBUTTON C/W IL & EOL RESISTOR FOR HP/MP/FILTRATION PUMPS (NC/NC - LATCH/LOCKABLE) | RSTAHL, BARTEC, IDEC, ALLEN BRADLEY or Equal/ /EU/G7/Singapore, Mexico, Australia |
8003/121-009 or Equal |
6 | LAMP INDICATOR FOR PUMP RUNNING/ WELL DISCREPANCY ALARM | RSTAHL, BARTEC, IDEC, ALLEN BRADLEY or Equal/ /EU/G7/Singapore, Mexico, Australia |
8013/311-al or Equal |
6 | ESD/USD PUSH BUTTON (NO/NC - LATCH, RED) C/W IL & EOL RESISTOR |
RSTAHL, BARTEC, IDEC, ALLEN BRADLEY or Equal/ /EU/G7/Singapore, Mexico, Australia |
8003/111-010 or Equal |
4 | ILLUMINATED PUSH BUTTON C/W IL & EOL RESISTOR FOR WELL SELECTION (NO/NO, PUSH/PULL TYPE) |
RSTAHL, BARTEC, IDEC, ALLEN BRADLEY or Equal/ /EU/G7/Singapore, Mexico, Australia |
800T-FXQH24GA2Y or Equal |
1 | INSTALLATION SWITCH 8030 SERIES. ON-OFF SWITCH, RATED VOLTAGE UP TO 500V, Eex ed IIC T6, IP65, ATEX CERTIFIED | RSTAHL, BARTEC, IDEC, ALLEN BRADLEY or Equal/ /EU/G7/Singapore, Mexico, Australia |
803051033 or Equal |
4 | FLUORESCENT FIXTURES. 2x36W, 110 TO 240VAC +/- 10%, 50/60HZ, ENTRIES: 3x1/2"NPT ALUMINIUM HUBS FOR USE IN CLASS 1 DIV. 2, Ex de IIC T4, IP66/67, FM APPROVED | STAHL, FEAM, Bulbs or Equal / EU/G7 | |
Qty | Descriptions | Manufacturer/CO | Model No. / Part No. |
Transmiter & Gauge | |||
2 | FLUORESCENT FIXTURES. 2x18W, 110 TO 240VAC +/- 10%, 50/60HZ, ENTRIES: 3x1/2"NPT ALUMINIUM HUBS FOR USE IN CLASS 1 DIV. 2, Ex de IIC T4, IP66/67, FM APPROVED | STAHL, FEAM, Bulbs or Equal / EU/G7 | |
JB&Cable glands, Lighting | |||
4 | Junction Box: Stainless steel 1.4404 (316L), Height: 400 mm, Width: 300 mm, Depth: 150 mm. Thickness: 3mm; Enclosure c/w hinge &lock Terminal accessories(End cover,end brackets, marker at both side perTB). 2 row x 20 terminal blocks 2.5,Vertical mounted on TS 35 DIN Rail, Left (10xM20 cable glands) Right (10xM20 cable gland) Bottom (4x4M40 cable glands) Fully tagname & Bolts &nuts. Classification hazadous: All junction boxes shall be Ex’e’/Exd type. Cable glands shall be dual certified to Ex’d’ and Ex’e’. IP65/IP66; Zone 2, Gas Group IIA, Temperature Class T3, Approved by PTB (Germany), BASEEFA (UK) or equivalent. |
Weidmuller, ROSE, FEAM,Hawke, CMP or Equal / EU/G7 | KTB MH 403015 S4E1/1194910000 or equal |
70 | Cable Glands: Eex-e brass cable gland M20; Zone 2, Gas Group IIA, Temperature Class T3 c/w locknut, earth tag, ETS & PVC Shroud; Approved by PTB (Germany), BASEEFA (UK) or equivalent. |
Hawke, CMP or Equal / EU/G7 | |
10 | Cable Glands: Eex-e brass cable gland M25; Zone 2, Gas Group IIA, Temperature Class T3 c/w locknut, earth tag, ETS & PVC Shroud; Approved by PTB (Germany), BASEEFA (UK) or equivalent. |
Hawke, CMP or Equal / EU/G8 | |
Qty | Descriptions | Manufacturer/CO | Model No. / Part No. |
Transmiter & Gauge | |||
5 | Cable Glands: Eex-e brass cable gland M32; Zone 2, Gas Group IIA, Temperature Class T3 c/w locknut, earth tag, ETS & PVC Shroud; Approved by PTB (Germany), BASEEFA (UK) or equivalent. |
Hawke, CMP or Equal / EU/G9 | |
4 | LIGHTING FIXTURES: Explosion proof Ex e lighting fixtures are applicable for hazardous areas, Zone 2, Gas Group IIA, Temperature Class T3. IP 65/IP66 They are designed to meet IEC, Ex and maritime requirements. Number of lamps: 2 pcs x 36W Number of cable entries: 2Mx25 with 2 brass blind plugs Stainless Steel AISI 316L Body material Voltage: 220-250 VAC; 60Hz; Approved by PTB (Germany), BASEEFA (UK) or equivalent |
Glamox, COOPER CROUSE - HINDS, FEAM or Equal |
MAXS67 218HF 2-5/5-6 TW PC B25 or equal |
2 | EMEGENCY-LIGHTING FIXTURES WITH BATTERY: Explosion proof Ex e lighting fixtures are applicable for hazardous areas, Zone 2, Gas Group IIA, Temperature Class T3. IP 65/IP66 They are designed to meet IEC, Ex and maritime requirements. Number of lamps: 2 pcs 2 pcs x 36W Number of cable entries: 2Mx25 with 2 brass blind plugs Stainless Steel AISI 316L Body material Operating time with self battery: 2 hours Voltage: 220-250 VAC; 60Hz; Approved by PTB (Germany), BASEEFA (UK) or equivalent |
Glamox, COOPER CROUSE - HINDS, FEAM or Equal |
eLLK 92036/36 NIB or equal |
10 | Hydraulic Oil Aqualink HT-804 for testing and first fill (200 Litters/drum ) |