Sunday, January 6, 2013

KHO HÀNG thiết bị tự động GNN | 06

Sheet Gasket 2mmT x 1500mm(w) x 1500mm(L) P200 Novaphis SSTC
Sheet Gasket 3mmT x 1000mm(w) x 1000mm(L) P200 Novaphis SSTC
Sheet Gasket 2mmT x 1000mm(w) x 1000mm(L) Novapress Basic ZW8800
Sheet Gasket 3mmT x 1000mm(w) x 1000mm(L) Novapress Basic ZW8800
Sheet Gasket 2mmT x 1500mm(w) x 1500mm(L) Novapress Basic ZW8800
Name S/N Notes
Heat exchanger PARKER 473068 spare part of CRD 1560
spare part of CRD 1560
include: Valves and gas filter 
STT Đặc Điểm Kỹ Thuật Mã Code
1 Setavap Vapour Pressure Analyser 80000-0U
Supplier: Stanhope-seta-UK
METHODS: ASTM D5188, ASTM D5191,
Correlates with: D323; D2533; D4953; D5482; D6378; IP 69; IP 402 (obs); ISO 3007; EN 12 (obs); JIS K2258; NF M07-079, EN 13016-1, EN 13016-2, IP 394, IP 409
The Setavap Analyser is an automatic multi-mode vapour pressure tester with a test pressure range of 0-600kPa and a temperature range from 25°C below ambient to 100°C. The instrument is fully automatic, including the septum change, sample draining, and print-out of test results.
The instrument features six modes of operation, including a Reid vapour pressure mode. In the vapour pressure modes, the operator can select single or multiple vapour pressure tests on a sample at static, ramping or stepped temperatures. The vapour-liquid mode enables determination of the temperature which produces a pre-set pressure.
All functions are accessed via the membrane keypad/digital display, while audible and visual prompts advise the status of the instrument and progress of the tests. Test results along with time, date, and sample identity are output via the integral printer and RS232 port. Pressure can be presented in kPa, psi, kg/cm2, mbar, mmHg, or in Hg.
Calibration is automated and can be carried out at full vacuum, atmospheric pressure, or high pressure. A calibration certificate can be printed out.
SPECIFICATIONS
Test Temperature Range: 25°C below ambient to 100°C (resolution 0.1°C) (45°F below ambient to 212°F)
Temperature Resolution:
0.1°C (0.2°F)
Units of Temperature:
°C or °F
Test Pressure:
Range 0 to 700kPa
Pressure Resolution:
0.1kPa (0.1psi)
Units of Pressure:
kPa, psi, (lbf/in2) kg/cm2, mbar, mmHg, in Hg (user selectable)
Reid Mode:
Display shows RVP equivalent
Chamber:
Volume 15ml ±1%
Vacuum:
Requirement better than 0.01kPa (abs)
Computer:
 Interface RS232C
Voltage:
220/240V, 50/60Hz (switchable)
Power: 
200W
Size:
(HxWxD) 35 x 45 x 37cm
Weight:
 22.8kg
Supplied with:
5ml syringe, 3 needles, septum strips, paper/ink package, flask, mains lead and instruction manual.
Required Accessories
Vacuum Pump 22422-6 P
Syringe 5ml c/w Luer Lock 81003-001
Needle, pack of 2 81003-002
Paper/Ink Package        40000-007
Septum Strip  (5)        80000-016
Flask - Used Sample (5)  80000-017
SETA Digital Thermometer 99922-0
Port.Digital Barometer   99910-0
Snowpack Major Dry Ice
SPECIFICATIONS
Pellet/Block Size (approx)  500g (1.1 lb)
Injection Time (approx)  2.5 minutes
Size (HxWxD)  28 x 15 x 15cm
Weight  0.8kg
70210-0
Cylinder Gas CO2,VN
Seta Cooling Unit 22090-0
Permits LPG samples to be taken from pipelines or tanks whilst maintaining the gas in liquid phase. 
In operation the cooling unit is filled with solid carbon dioxide and
the inlet is connected to the sampling point. The sample is drawn into the cooling unit until vapour overflow is observed after which it is isolated by closing the valves. Liquefied gas is then drawn from the bottom of the cooling unit via the outlet tube which may be connected to a pressure sampling, vapour pressure cylinder or similar test vessel.

No comments: