Sheet Gasket | 2mmT x 1500mm(w) x 1500mm(L) | P200 Novaphis SSTC |
Sheet Gasket | 3mmT x 1000mm(w) x 1000mm(L) | P200 Novaphis SSTC |
Sheet Gasket | 2mmT x 1000mm(w) x 1000mm(L) | Novapress Basic ZW8800 |
Sheet Gasket | 3mmT x 1000mm(w) x 1000mm(L) | Novapress Basic ZW8800 |
Sheet Gasket | 2mmT x 1500mm(w) x 1500mm(L) | Novapress Basic ZW8800 |
Name | S/N | Notes |
Heat exchanger PARKER | 473068 | spare part of CRD 1560 |
spare
part of CRD 1560 include: Valves and gas filter |
||
STT | Đặc Điểm Kỹ Thuật | Mã Code |
1 | Setavap Vapour Pressure Analyser | 80000-0U |
Supplier: Stanhope-seta-UK | ||
METHODS: ASTM D5188, ASTM D5191, Correlates with: D323; D2533; D4953; D5482; D6378; IP 69; IP 402 (obs); ISO 3007; EN 12 (obs); JIS K2258; NF M07-079, EN 13016-1, EN 13016-2, IP 394, IP 409 |
||
The Setavap Analyser is an automatic multi-mode vapour pressure tester with a test pressure range of 0-600kPa and a temperature range from 25°C below ambient to 100°C. The instrument is fully automatic, including the septum change, sample draining, and print-out of test results. | ||
The instrument features six modes of operation, including a Reid vapour pressure mode. In the vapour pressure modes, the operator can select single or multiple vapour pressure tests on a sample at static, ramping or stepped temperatures. The vapour-liquid mode enables determination of the temperature which produces a pre-set pressure. | ||
All functions are accessed via the membrane keypad/digital display, while audible and visual prompts advise the status of the instrument and progress of the tests. Test results along with time, date, and sample identity are output via the integral printer and RS232 port. Pressure can be presented in kPa, psi, kg/cm2, mbar, mmHg, or in Hg. | ||
Calibration is automated and can be carried out at full vacuum, atmospheric pressure, or high pressure. A calibration certificate can be printed out. | ||
SPECIFICATIONS | ||
Test Temperature Range: 25°C below ambient
to 100°C (resolution 0.1°C) (45°F below ambient to 212°F) Temperature Resolution: 0.1°C (0.2°F) Units of Temperature: °C or °F Test Pressure: Range 0 to 700kPa Pressure Resolution: 0.1kPa (0.1psi) Units of Pressure: kPa, psi, (lbf/in2) kg/cm2, mbar, mmHg, in Hg (user selectable) Reid Mode: Display shows RVP equivalent Chamber: Volume 15ml ±1% Vacuum: Requirement better than 0.01kPa (abs) Computer: Interface RS232C Voltage: 220/240V, 50/60Hz (switchable) Power: 200W Size: (HxWxD) 35 x 45 x 37cm Weight: 22.8kg |
||
Supplied with: 5ml syringe, 3 needles, septum strips, paper/ink package, flask, mains lead and instruction manual. |
||
Required Accessories | ||
Vacuum Pump | 22422-6 P | |
Syringe 5ml c/w Luer Lock | 81003-001 | |
Needle, pack of 2 | 81003-002 | |
Paper/Ink Package | 40000-007 | |
Septum Strip (5) | 80000-016 | |
Flask - Used Sample (5) | 80000-017 | |
SETA Digital Thermometer | 99922-0 | |
Port.Digital Barometer | 99910-0 | |
Snowpack Major Dry Ice SPECIFICATIONS Pellet/Block Size (approx) 500g (1.1 lb) Injection Time (approx) 2.5 minutes Size (HxWxD) 28 x 15 x 15cm Weight 0.8kg |
70210-0 | |
Cylinder Gas CO2,VN | ||
Seta Cooling Unit | 22090-0 | |
Permits LPG samples to be taken from pipelines or tanks whilst maintaining the gas in liquid phase. | ||
In operation the cooling unit is filled with solid carbon
dioxide and the inlet is connected to the sampling point. The sample is drawn into the cooling unit until vapour overflow is observed after which it is isolated by closing the valves. Liquefied gas is then drawn from the bottom of the cooling unit via the outlet tube which may be connected to a pressure sampling, vapour pressure cylinder or similar test vessel. |